ECB geomembrane

Function: seepage control and isolation
Application: ● seepage control of landfill, sewage or waste residue treatment site. River dike, lake dam, tailings dam, sewage dam and reservoir area, channel and storage pool (pit, mine). ● metro, basement and tunnel, tunnel anti-seepage lining. ● subgrade and other foundation salt seepage prevention. ● horizontal impervious blanket in front of dike and dam, vertical impervious layer of foundation, construction cofferdam and waste dump. ● marine and freshwater farms. ● foundation of highway, expressway and railway; waterproof layer of expansive soil and collapsible loess. ● roof seepage prevention.
Products: including LDPE geomembrane, LDPE geomembrane, HDPE geomembrane, EVA geomembrane, ECB geomembrane, PVC geomembrane, rough surface geomembrane, etc.
Technical index of ECB geomembrane
Serial number
project
index
One
Thickness mm
0.2~4
Two
Width m
2.5~8m
Three
Tensile strength (vertical and horizontal) MPa
≥16
Four
Elongation at break (longitudinal and transverse)%
≥550
Five
Right angle tear strength n / mm
≥60
Six
Water vapor permeability coefficient (g, cm / C m2. S.pa)
<1.0×10-13
Seven
Operating temperature range
+70℃~-70℃